API field
Grid limitation: account as separate loss
Whether the grid-limit clip gets its own loss row
What it is
Whether the energy the grid limitation removes is shown as its own row. When it is, the array still runs at the limited operating point, and the inverter output and its loss rows are reported as if the limit were absent.
Typical values and how to get it
Off, unless the report should show the grid limitation apart from the inverter sizing.
Values
true: the clipped energy is the Unused energy (grid limitation) row · false (default): the clipped energy counts in Inverter Loss over nominal inv. power
API
ac_losses.grid_limit_separate_loss