pvperfsolar performance modeling

Reference

API field

Fraction for electrical effect

Multiplier on the electrical shading loss

Unit –

What it is

A multiplier on the part of the electrical shading loss that exceeds the light the shadow covers. At 1 the whole strip loses its direct light when a shadow reaches it. Smaller values describe layouts where part of the strip keeps producing.

Typical values and how to get it

1 unless a measured layout justifies less. If not given: 1: the electrical shading counts in full.

How it is applied

Gel=Geff−fel max⁡ ⁣(0, Felec−Fsh)GbG_{el} = G_{\text{eff}} - f_{\text{el}}\,\max\!\left(0,\ F_{\text{elec}} - F_{\text{sh}}\right) G_{\text{b}}

where

Symbol Meaning Unit
GelG_{el} the effective irradiance the module model receives W/m²
GeffG_{\text{eff}} the effective irradiance on the plane after the linear shading W/m²
felf_{\text{el}} this input —
FelecF_{\text{elec}} the share of the collector width the electrical model counts as lost, set by the strips the shadow reaches —
FshF_{\text{sh}} the shaded share of the collector width, the linear loss —
GbG_{\text{b}} the direct light on the plane after the horizon, the incidence-angle loss and soiling W/m²

API

array.fraction_for_electrical

Symbols follow the symbol registry.