API field
Loss fraction at STC (DC circuit)
Resistive loss of the DC cables at full power
Unit %
What it is
The resistive loss of the DC cables when the array runs at standard test conditions, as a fraction of the array power. With the default wiring model (I²R on the MPP current) the model turns it into a wiring resistance and applies the loss at the actual current of every timestep, so the annual loss is smaller than this fraction.
Typical values and how to get it
1.5 % is a usual design value. A cable schedule gives it exactly.
How it is applied
where
| Symbol | Meaning | Unit |
|---|---|---|
| the wiring resistance of one inverter's array | Ω | |
| this input as a fraction | — | |
| the array's maximum-power voltage at standard test conditions | V | |
| the array's maximum-power current at standard test conditions | A | |
| the wiring loss of the timestep | W | |
| the array current of the timestep | A |
API
dc_losses.dc_wiring_loss_at_stc — sent as a fraction 0–1
Symbols follow the symbol registry.