pvperfsolar performance modeling

Reference

API field

String voltage mismatch

Loss from parallel strings that differ from each other

Unit %

What it is

The power lost because parallel strings on one inverter do not have the same voltage, as a fraction.

Typical values and how to get it

A common design range is 0.15 % to 0.5 %. If not given: 0: no string mismatch.

How it is applied

Pafter=Pbefore (1−fstr)P_{\text{after}} = P_{\text{before}}\,(1 - f_{\text{str}})

where

Symbol Meaning Unit
PafterP_{\text{after}} the array DC power after this derate W
PbeforeP_{\text{before}} the array DC power before it W
fstrf_{\text{str}} this input as a fraction —

API

dc_losses.string_mismatch_loss — sent as a fraction 0–1

Symbols follow the symbol registry.