Loss row
Array virtual energy at MPP
The DC energy the array could deliver at its best operating point
Unit kWh/kWp
What this step does
The row is the DC energy the array would deliver if the inverter always operated it at its maximum-power point: the nominal energy after the rear-side gain, the irradiance-level, temperature and spectral rows, the flat derates and the wiring loss.
The math
where
| Symbol | Meaning | Unit |
|---|---|---|
| the array energy at maximum power | kWh/kWp | |
| the array nominal energy | kWh/kWp | |
| the rows between the two, from the rear-side gain to the DC wiring loss, gains positive and losses negative | kWh/kWp |
Reading the number
A total, positive: about 85 to 92 % of the nominal energy on a monofacial system. Hot sites and poorly ventilated rooftop modules sit at the low end. A bifacial rear side adds to it.
API
loss.earr_mpp