Inverter Loss due to max. input current

Energy lost to the inverter's DC input current limit

Unit kWh/kWp

What this step does

The row measures the array energy lost when the array current exceeds the inverter's DC current limit. The inverter raises the array voltage until the current meets the limit. When the power limit also applies, the inverter holds the higher of the two voltages: Inverter Loss over nominal inv. power takes the loss down to the AC-limit voltage, and this row only the further loss when the current limit sets a higher voltage. Equation 2 holds for the Operating point on the array's I–V curve option of the Model tab's Inverter operating limits step. Under Cap the power, no I–V curve, the row is the maximum power times the share of the current above the limit; under Clip at the AC nameplate it is zero.

The math

  1. Running total
  2. Loss at a timestep
Eafter=Ebefore−Erow,Erow=Δt1000 PDC∑iLi(1)E_{after} = E_{before} - E_{row},\qquad E_{row} = \frac{\Delta t}{1000\,P_{DC}}\sum_i L_i \tag{1} Li=Ninv[Pbefore,i−UI,i Imax](2)L_i = N_{inv}\left[P_{before,i} - U_{I,i}\,I_{max}\right] \tag{2}

where

Symbol Meaning Unit
EbeforeE_{before} the running total of the loss diagram before this row kWh/kWp
EafterE_{after} the running total after this row kWh/kWp
ErowE_{row} the row taken as a loss kWh/kWp
Δt\Delta t the length of one timestep hours
PDCP_{DC} the DC nameplate of the system kWp
LiL_i the power lost at timestep ii over the whole system W
NinvN_{inv} the number of inverters —
Pbefore,iP_{before,i} one inverter's array power before this row at timestep ii W
UI,iU_{I,i} the voltage at which the array current equals the limit V
ImaxI_{max} the inverter's DC current limit A

Reading the number

A loss, negative. Usually zero on utility and rooftop systems. It appears when an input carries more parallel strings than its current limit allows.