Loss row
Inverter Loss over nominal inv. power
Power the array could make but the inverter cannot pass
Unit kWh/kWp
What this step does
The array energy lost when the array could deliver more than the inverter's AC limit: the nameplate, lowered by the temperature derating and, unless the Losses tab shows the grid limitation on its own row, by the grid power limitation. The inverter moves the array away from its maximum-power point until the output meets the limit. The Model tab's Inverter operating limits step sets how the operating point moves. The Model tab's MPPT minimum loss row step decides whether the energy lost while the array voltage sits below the MPPT window counts here or in Inverter Loss due to voltage threshold.
The math
where
| Symbol | Meaning | Unit |
|---|---|---|
| the running total of the loss diagram before this row | kWh/kWp | |
| the running total after this row | kWh/kWp | |
| the row taken as a loss | kWh/kWp | |
| the length of one timestep | hours | |
| the DC nameplate of the system | kWp | |
| the power lost at timestep over the whole system | W |
Reading the number
A loss, negative. The DC-to-AC ratio and the derating schedule set it. A ratio of 1.35 loses about 3 % over a year at a sunny site; a rooftop system with a ratio near 1.1 loses a few tenths of a percent.
API
loss.inv_p_clip
Symbols follow the symbol registry.