Loss row

Power factor (reactive power)

Energy the power factor costs against 1

Unit kWh/kWp

What this step does

The row appears when the Model tab's Power factor step is set to Own row and the power factor is below 1. The inverter pass runs a second time at a power factor of 1 when the inverter's nominal power is an apparent power, and the AC chain is computed a second time at a power factor of 1 on the same inverter output. The clipping row, the inverter output and each resistive AC row then show their values at a power factor of 1, and this row takes the difference. The energy injected into the grid is the same as with the cost inside the other rows.

The math

  1. Running total
  2. Loss at a timestep
Eafter=Ebefore−Erow,Erow=Δt1000 PDC∑iLi(1)E_{after} = E_{before} - E_{row},\qquad E_{row} = \frac{\Delta t}{1000\,P_{DC}}\sum_i L_i \tag{1} Li=Ninv(Pout,1,i−Pout,i)+∑r(Lr,i−Lr,1,i)(2)L_i = N_{inv}\left(P_{out,1,i} - P_{out,i}\right) + \sum_r \left(L_{r,i} - L_{r,1,i}\right) \tag{2}

where

Symbol Meaning Unit
EbeforeE_{before} the running total of the loss diagram before this row kWh/kWp
EafterE_{after} the running total after this row kWh/kWp
ErowE_{row} the row taken as a loss kWh/kWp
Δt\Delta t the length of one timestep hours
PDCP_{DC} the DC nameplate of the system kWp
LiL_i the power lost at timestep ii over the whole system W
NinvN_{inv} the number of inverters —
Pout,1,iP_{out,1,i} the output of one inverter at timestep ii with a power factor of 1, in W; equal to Pout,iP_{out,i} when the nominal power is an active power —
Pout,iP_{out,i} the output of one inverter at timestep ii W
Lr,iL_{r,i} the loss of resistive AC row rr at timestep ii W
Lr,1,iL_{r,1,i} the same loss at a power factor of 1 W

Reading the number

A loss, negative. Zero at a power factor of 1. The resistive share is 1/PF² − 1 of the resistive AC losses at a power factor of 1, 23 % of them at 0.9. The inverter share needs an apparent-power nominal and grows with the hours the inverter clips. On the default request at 0.9 with an apparent-power nominal the row is 0.3 % of the inverter output.