pvperfsolar performance modeling

Reference

Loss row

Global incident rear side

Energy from the light on the rear of bifacial modules

Unit kWh/kWp

What this step does

The row adds to the array energy the energy from the light on the rear side of bifacial modules. The rear irradiance is converted at the rated efficiency and scaled by the bifaciality factor. The Model tab's Rear side and front ground reflection step computes the rear irradiance.

The math

  1. Running total
  2. Gain at a timestep
Eafter=Ebefore+Erow,Erow=Δt1000 PDC∑iLi(1)E_{after} = E_{before} + E_{row},\qquad E_{row} = \frac{\Delta t}{1000\,P_{DC}}\sum_i L_i \tag{1} Li=N Pnom bf Grear,iGref(2)L_i = N\,P_{nom}\,b_f\,\frac{G_{rear,i}}{G_{ref}} \tag{2}

where

Symbol Meaning Unit
EbeforeE_{before} the running total of the loss diagram before this row kWh/kWp
EafterE_{after} the running total after this row kWh/kWp
ErowE_{row} the row, a gain kWh/kWp
Δt\Delta t the length of one timestep hours
PDCP_{DC} the DC nameplate of the system kWp
LiL_i the power gained at timestep ii over the whole system W
NN the number of modules in the system —
PnomP_{nom} the module nameplate power at standard test conditions W
bfb_f the bifaciality factor of the module —
Grear,iG_{rear,i} the irradiance on the rear side at timestep ii W/m²
GrefG_{ref} the reference irradiance of the standard test conditions (1,000 W/m²) W/m²

Reading the number

A gain, positive: typically 3 to 10 % of the nominal energy on a bifacial utility plant. A bright ground, modules mounted high, a low ground cover ratio and a high bifaciality factor raise it. Monofacial modules and rooftop systems show zero.

References

  1. Marion et al. 2017, A practical irradiance model for bifacial PV modules, NREL/CP-5J00-67847

API

loss.rear_incident

Symbols follow the symbol registry.