pvperfsolar performance modeling

Reference

Loss row

Unavailability of the system

Energy lost to outages, applied last

Unit kWh/kWp

What this step does

The energy lost to outages and maintenance. It acts on the grid energy, as the last row: a flat share of the exported power on every timestep, and the whole inverter output inside a shutdown period. Inside a shutdown period the other AC rows and the day auxiliaries are zero, and only the night auxiliaries are drawn.

The math

  1. Running total
  2. Loss at a timestep
Eafter=Ebefore−Erow,Erow=Δt1000 PDC∑iLi(1)E_{after} = E_{before} - E_{row},\qquad E_{row} = \frac{\Delta t}{1000\,P_{DC}}\sum_i L_i \tag{1} Li={Ninv Pinv,iinside a shutdown periodu Pin,iotherwise, when Pin,i>0(2)L_i = \begin{cases} N_{inv}\,P_{inv,i} & \text{inside a shutdown period} \\ u\,P_{in,i} & \text{otherwise, when } P_{in,i} > 0 \end{cases} \tag{2}

where

Symbol Meaning Unit
EbeforeE_{before} the running total of the loss diagram before this row kWh/kWp
EafterE_{after} the running total after this row kWh/kWp
ErowE_{row} the row taken as a loss kWh/kWp
Δt\Delta t the length of one timestep hours
PDCP_{DC} the DC nameplate of the system kWp
LiL_i the power lost at timestep ii over the whole system W
NinvN_{inv} the number of inverters —
Pinv,iP_{inv,i} the output of one inverter at timestep ii, taken as 0 when it is negative W
uu the flat unavailability fraction —
Pin,iP_{in,i} the power after the auxiliaries at timestep ii W

Reading the number

A loss, negative. 1 to 2 % for a utility system, often 0 for a rooftop system. The fraction, or the season and length of the shutdown periods, set it.

API

loss.unavailability

Symbols follow the symbol registry.