API field
Module
The electrical description of one PV module
What it is
The module section describes one PV module: its nameplate power and size, the current and voltage at standard test conditions, the temperature coefficients, the internal resistances of the one-diode circuit model, an optional measured incidence-angle table, the cell technology and the bifaciality factor. It can be given inline, by the id of an uploaded PAN file, or by the id of a library module. Inline, the nameplate power alone is enough for the PVWatts DC model.
Typical values and how to get it
Upload the manufacturer's PAN file when you have it. Otherwise pick a library module of the same class; library entries are converted from the CEC database and say so.
References
- De Soto, Klein & Beckman 2006, Improvement and validation of a model for photovoltaic array performance, Solar Energy 80(1) 78–88
- Mermoud & Lejeune 2010, Performance assessment of a simulation model for PV modules of any available technology, 25th European Photovoltaic Solar Energy Conference
API
module