pvperfsolar performance modeling

Reference

Loss row

Solar energy at the POI (before storage)

The system's grid injection before the battery

Unit kWh/kWp

What this step does

The row opens the storage block with the system's energy injected into the grid before the battery acts, equal to the Active Energy injected into grid row.

The math

  1. The starting total
Eafter=1PDC∑ipi Δt(1)E_{after} = \frac{1}{P_{DC}} \sum_i p_i\,\Delta t \tag{1}

where

Symbol Meaning Unit
EafterE_{after} the running total after this row kWh/kWp
PDCP_{DC} the system DC nameplate kWp
pip_i the system's grid injection before the battery at timestep ii kW
Δt\Delta t the length of one timestep h

Reading the number

A total, positive: the system's specific yield, about 1,200 to 2,200 kWh/kWp a year for a utility plant and 900 to 1,500 kWh/kWp for a rooftop system, set by the site's sunlight and the losses above it.

API

storage.solar

Symbols follow the symbol registry.