API field
NOCT standoff adjustment
The rise of the rated NOCT for modules mounted close to a roof
Unit °C
What it is
Used by the NOCT model with the module's rated NOCT: the amount added to the rated NOCT for the gap between the modules and the roof. 0 °C for a ground or rack mount or a gap above 3.5 inch (8.9 cm), 2 °C for 2.5 to 3.5 inch, 6 °C for 1.5 to 2.5 inch, 11 °C for 0.5 to 1.5 inch and 18 °C below 0.5 inch. No other model reads it.
Typical values and how to get it
0 °C for ground mounts and trackers; the value of the mounting gap for a roof. If not given: 0 °C, whatever the racking.
References
- Gilman, DiOrio, Freeman, Janzou, Dobos & Ryberg 2018, SAM Photovoltaic Model Technical Reference Update, NREL/TP-6A20-67399
API
thermal.noct_standoff_adjust_c