API field
SAPM coefficient b
How fast the SAPM temperature rise falls with wind; empty = King's table
Unit s/m
What it is
The coefficient b of King's Sandia (SAPM) temperature model: how fast the module's temperature rise falls with wind speed, per m/s. Used only by the SAPM model. Give a, b and ΔT together. If not given, King's table by racking and module (see SAPM coefficient a).
Typical values and how to get it
Leave it empty for King's table; −0.0594 s/m for open-rack glass/glass, −0.0750 s/m for open-rack glass/polymer, −0.0471 s/m for close roof mount.
References
- King, Boyson & Kratochvil 2004, Photovoltaic Array Performance Model, Sandia report SAND2004-3535
- pvlib-python 0.16.1 source code (github.com/pvlib/pvlib-python), reference implementation: pvlib/temperature.py, sapm_cell() and fuentes()
API
thermal.sapm_b