Model option
Flat fraction
A fixed fraction of the inverter output, the night consumption included
Inputs used: AC circuit: loss fraction at STC, AC wiring model, AC power reference, Power factor
Method
The loss is the same fraction of the inverter output at every load. On a timestep the inverter draws its night consumption, the fraction of that consumption is drawn as well. The transformer and the later AC losses act on the output after this loss. This is the AC wiring loss of SAM's detailed photovoltaic model.
The math
where
| Symbol | Meaning | Unit |
|---|---|---|
| the AC cable loss of one inverter | W | |
| the AC wiring loss, a fraction | — | |
| the inverter's AC output, negative while it draws its night consumption | W |
References
- NREL SAM Simulation Core (SSC) source code, release 2026.7.3, github.com/NatLabRockies/ssc: ssc/cmod_pvsamv1.cpp, the AC wiring, transformer and transmission losses in exec(); shared/lib_power_electronics.cpp, Transformer::transformerLoss()
API
ac_losses.ohmic_model = flat
Symbols follow the symbol registry.