pvperfsolar performance modeling

Reference / AC ohmic wiring

Model option

k·P² on the inverter output

The loss grows with the square of the inverter output

Inputs used: AC circuit: loss fraction at STC, AC wiring model, AC power reference, Power factor

Method

The loss is the fraction at the power reference scaled by the square of the inverter output, as the loss in a resistance grows with the square of the current. The current rises as the power factor falls, so the loss is divided by its square. On a timestep the inverter draws its night consumption, there is no cable loss.

The math

Lac=fac Pout2Pref cos⁡2φ(1)L_{ac} = f_{ac}\,\frac{P_{out}^2}{P_{ref}\,\cos^2\varphi} \tag{1}

where

Symbol Meaning Unit
LacL_{ac} the AC cable loss of one inverter W
facf_{ac} the AC wiring loss at the power reference, a fraction —
PoutP_{out} the inverter's AC output W
PrefP_{ref} the power reference of one inverter W
cos⁡φ\cos\varphi the power factor —

References

  1. PVsyst 8 help, AC losses

API

ac_losses.ohmic_model = ohmic_i2r

Symbols follow the symbol registry.