Reference / One-diode STC point
Model option
Maximum at the nominal power
The curve's maximum power at standard test conditions equals the nameplate
Inputs used: MPP voltage, MPP current, Nameplate power
Method
The ideality factor is the one at which the maximum power of the curve at standard test conditions equals the nameplate power (1). The array nominal energy is counted from the nameplate (2). The datasheet maximum-power point is not used.
The math
- The third point
- The array nominal energy
where
| Symbol | Meaning | Unit |
|---|---|---|
| the module current at voltage on the fitted curve | A | |
| the module's nameplate power | W | |
| the irradiance of standard test conditions, 1000 W/m² | W/m² | |
| the cell temperature of standard test conditions, 25 °C | K | |
| the array nominal power of the timestep | W | |
| the number of modules | — | |
| the effective irradiance | W/m² |
References
- Mermoud & Lejeune 2010, Performance assessment of a simulation model for PV modules of any available technology, 25th European Photovoltaic Solar Energy Conference
API
options.module_stc_point = pnom
Symbols follow the symbol registry.