Reference / Grid limit ceiling
Model option
Run to the ceiling
The inverters run to the ceiling, and the AC losses are taken there
Inputs used: Grid power limitation, Grid limitation at, Grid limitation: account as separate loss, Grid limit ceiling
Method
On a timestep where the array could deliver more, each inverter brings its output down to the ceiling of the Grid power limitation step (1). The AC losses after the inverters are taken on that output.
The math
where
| Symbol | Meaning | Unit |
|---|---|---|
| the output of one inverter. On a timestep the limit binds | W | |
| the AC ceiling of one inverter. Set by the Grid power limitation step | W |
References
- PVsyst 8 help, Grid power limitation
API
ac_losses.grid_limit_ceiling = exact
Symbols follow the symbol registry.