pvperfsolar performance modeling

Reference

Model step

Where the correction acts

Before or after the cell temperature

Inputs used: Spectral application, Spectral air mass, Air-mass cap, Station pressure, Altitude

What it is

The spectral modifier of Lee and Panchula always multiplies the irradiance that the module model converts. The cell temperature is computed from an irradiance too, and this step decides whether it is computed from the corrected or from the uncorrected irradiance. The modifier then enters before the cell temperature, point A of Figure 10, or after it, point B. The choice also sets the air-mass formula and what the spectral row of the loss diagram measures. The step is live only while the spectral correction is Lee and Panchula.

Where the spectral modifier M enters the chain

Options

References

  1. Lee & Panchula 2016, Spectral correction for photovoltaic module performance based on air mass and precipitable water, IEEE 43rd Photovoltaic Specialists Conference

API

spectral.application = power_ratio | effective_irradiance, spectral.airmass_method = kasten_1966 | kasten_young_1989