pvperfsolar performance modeling

Reference / Unavailability

Model option

Flat fraction and periods

Shutdown periods and a flat fraction of the grid energy

Inputs used: Unavailability: flat energy fraction, Unavailability periods, Model the unavailability

Method

Inside a shutdown period the system delivers nothing to the grid. The AC losses and the day auxiliaries are zero there, the night auxiliaries are still drawn, and the whole inverter output counts as unavailability. A timestep belongs to a period when its start falls inside it; the start of a period is read in the weather file's local standard time. On every other timestep with a positive energy, the flat fraction takes its share of the energy that would reach the grid, as the last step of the chain.

The math

  1. Outside the periods
  2. Inside a period
Egrid=(1−u) Eavail(Eavail>0)(1)E_{grid} = (1 - u)\,E_{avail} \quad (E_{avail} > 0) \tag{1} LU=max⁡(Einv, 0),Egrid=min⁡(Einv, 0)−Enight(2)L_U = \max(E_{inv},\ 0),\qquad E_{grid} = \min(E_{inv},\ 0) - E_{night} \tag{2}

where

Symbol Meaning Unit
EgridE_{grid} the energy injected into the grid in the timestep Wh
uu the flat unavailability fraction —
EavailE_{avail} the energy of the timestep after the auxiliaries Wh
LUL_U the unavailability loss of the timestep Wh
EinvE_{inv} the output of the inverters in the timestep Wh
EnightE_{night} the night draw of the auxiliaries in the timestep, zero while the sun is up Wh

References

  1. PVsyst 8 help, Unavailability loss
  2. Analysis of PVsyst 8.1.5 outputs shows this convention in its results.

API

ac_losses.use_unavailability = true

Symbols follow the symbol registry.