Model option
NOCT, module's rated NOCT
The NOCT model with the module's rated NOCT and a standoff adjustment
Inputs used: Thermal loss factor Uc (constant), Thermal loss factor Uv (wind), Absorptivity, Thermal inertia, Module unit mass, NOCT standoff adjustment, SAPM coefficient a, SAPM coefficient b, SAPM ΔT, CEC database parameters, Racking type, Ambient temperature, Wind speed
Method
The equation is that of the NOCT option (1): the rise at nominal operating conditions, 800 W/m² at 20 °C ambient, scaled by the irradiance, reduced by the module efficiency over the transmittance-absorptance product, and cooled by the wind with the weather file's wind speed times 0.51. The nominal operating cell temperature is the module's own: the rated NOCT of its CEC database entry plus the standoff adjustment of the Physics tab. The irradiance is the effective irradiance on the front side, after the glass-reflection step and after the spectral modifier when that acts on the effective irradiance. Values the model fills in: a module without a rated NOCT (one read from a PAN file) uses 45 °C, and the run's warnings say so; the standoff adjustment is 0 °C if not given, the value for a ground or rack mount, whatever the racking.
Settings
| Mounting standoff | Adjustment of the NOCT |
|---|---|
| Ground or rack mount, or more than 3.5 inch (8.9 cm) from the roof | 0 °C |
| 2.5 to 3.5 inch (6.4 to 8.9 cm) | 2 °C |
| 1.5 to 2.5 inch (3.8 to 6.4 cm) | 6 °C |
| 0.5 to 1.5 inch (1.3 to 3.8 cm) | 11 °C |
| Less than 0.5 inch (1.3 cm) | 18 °C |
| Wind factor | 0.51 (arrays less than 6.7 m above the ground) |
The math
where
| Symbol | Meaning | Unit |
|---|---|---|
| the cell temperature | °C | |
| the ambient temperature | °C | |
| the effective irradiance on the front side | W/m² | |
| the module's rated NOCT plus the standoff adjustment | °C | |
| the module's reference efficiency | — | |
| the transmittance-absorptance product | — | |
| the wind speed at the modules | m/s | |
| the wind speed | m/s |
References
- Duffie & Beckman, Solar Engineering of Thermal Processes, 4th ed., Wiley 2013
- Gilman, DiOrio, Freeman, Janzou, Dobos & Ryberg 2018, SAM Photovoltaic Model Technical Reference Update, NREL/TP-6A20-67399
- NREL SAM Simulation Core (SSC) source code, release 2026.7.3, github.com/NatLabRockies/ssc: shared/lib_cec6par.cpp, cec6par_module_t and noct_celltemp_t; ssc/cmod_pvwattsv8.cpp, the module parameters of each module type