Model option
NOCT › Published
Duffie and Beckman's NOCT equation with the module's rated NOCT
Inputs used: Thermal loss factor Uc (constant), Thermal loss factor Uv (wind), Absorptivity, Thermal inertia, Module unit mass, NOCT standoff adjustment, Installed NOCT, SAPM coefficient a, SAPM coefficient b, SAPM ΔT, CEC database parameters, Racking type, Ambient temperature, Wind speed
Method
The cell temperature rise above the ambient air is the rise at nominal operating conditions, 800 W/m² at 20 °C ambient, scaled in proportion to the plane irradiance (1). The light the module turns into electricity does not heat it, so the rise is reduced by the module efficiency over the transmittance-absorptance product. The wind term scales the heat loss from its value at 1 m/s to the wind of the timestep. The irradiance is the plane irradiance after shading and soiling, before the glass reflection. The NOCT is the module's rated NOCT. A module without one takes 45 °C, with a notice.
Settings
| Setting | Value |
|---|---|
| Nominal operating cell temperature | the module's rated NOCT; 45 °C when it has none |
| Transmittance-absorptance product | 0.9 |
The math
where
| Symbol | Meaning | Unit |
|---|---|---|
| the cell temperature | °C | |
| the ambient temperature | °C | |
| the plane irradiance before the glass-reflection step | W/m² | |
| the nominal operating cell temperature | °C | |
| the module efficiency at standard test conditions | — | |
| the transmittance-absorptance product | — | |
| the wind speed | m/s |
References
- Duffie & Beckman, Solar Engineering of Thermal Processes, 4th ed., Wiley 2013
API
thermal.model = noct_published, thermal.transient = false
Symbols follow the symbol registry.