Reference / Electrical shading effect

Model option

According to strings

The strips a shadow touches lose their direct light

Inputs used: Strings on one rack, String layout, Cell height along the slope, Fraction for electrical effect, Device strings, Device string layout, Placement string, Twin half-cell layout, Cells in series, Cell strings in parallel, Width, Length (height), MPPT window minimum

Method

The collector width is divided into strips whose strings switch off independently. The strips are the strings on one rack (Racking tab), one when the input is blank, when they are stacked across the width. Strings side by side along the row form one strip, since a shadow on the row reaches every one of them. As the shadow climbs a strip, the strip's loss ramps from zero to the whole strip over one cell width, because a partly shaded cell limits the current of the whole string. With the geometric closed form of the Near shading step the ramp is not applied. The extra loss beyond the light the shadow removes is recorded as the electrical shading row, scaled by the fraction for electrical effect. Every width below is measured up the slope of the collector.

The math

felec=ffrac(∑kℓkWtot−Fsh),ℓk=sk+min⁡ ⁣(skc,1)(Wstrip−sk)(1)f_{elec} = f_{frac}\left(\frac{\sum_k \ell_k}{W_{tot}} - F_{sh}\right),\qquad \ell_k = s_k + \min\!\left(\frac{s_k}{c}, 1\right)(W_{strip} - s_k) \tag{1}

where

Symbol Meaning Unit
felecf_{elec} the extra fraction of the direct light lost to the electrical effect —
ffracf_{frac} the fraction for electrical effect —
ℓk\ell_k the width of strip kk counted as lost m
WtotW_{tot} the total row width m
FshF_{sh} the shaded fraction of the row —
sks_k the width of strip kk the shadow covers m
cc the width of one cell m
WstripW_{strip} the width of one strip, the collector width over the number of strips m

References

  1. PVsyst 8 help, Electrical effect according to module strings

API

array.shade_mode = electrical